Using ProLink
®
Software with Micro Motion
®
Transmitters
119
Configure Menu:
Transmitter Outputs
Configure Menu:
Transmitter Information
Configure Menu: EventsView Menu: Status
Configure Menu:
Characterize
Configure Menu:
Transmitter Variables
11 Configure Menu:
Transmitter Information
11.1 Overview
The Transmitter Information dialog box provides information about the
transmitter and sensor. Some information is entered by the user and can
be changed; some fields are read-only.
The Transmitter Information dialog box is divided into distinct "frames":
Transmitter Database, Pressure Input, Burst, and Sensor Database.
• The Transmitter Database frame contains text boxes for the
transmitter HART tag, serial number, configuration date, polling
address, a description, and a message. Display boxes indicate the
Micro Motion device identifier and transmitter software revision. If the
transmitter is a Version 3 RFT9739 in security mode 8, display boxes
also indicate security event register values.
• For an RFT9739, the Pressure Input frame contains a drop-down list
box that allows the user to configure the transmitter for pressure
compensation or viscosity measurement.
• For an RFT9739, RFT9712, or RFT9729, the Burst frame contains
option buttons that enable the transmitter to communicate in burst
mode under HART protocol at 1200 baud.
• For an RFT9739, RFT9712, or RFT9729, the Sensor Database
frame contains text boxes for entering the sensor serial number and
sensor type, and list boxes for choosing options that describe the
sensor lange, flow tube construction material, and liner material.
The user can change most transmitter information without affecting
flowmeter operation. However, the transmitter does use the data in the
Tag, Comm Addr, and Pressure Input fields. More information is
provided throughout this chapter.
To open the Transmitter Information dialog box, open the Configure
menu, then choose Transmitter Information. The Transmitter Information
dialog box appears, as depicted in:
•
Figure 11-1
for an RFT9739
•
Figure 11-2
for an IFT9701 or IFT9703
•
Figure 11-3
for an RFT9712 or RFT9729
Record transmitter information in the appropriate Transmitter
Configuration Worksheet, shown in
Appendix E
, page 183.
Comentarios a estos manuales